Installing sewers in a private home - it is a complex and responsible task, which can bring a lot of trouble the hosts. Considering all of the above, is it any wonder that many people are taking up sewage in your home, make mistakes, sometimes in large numbers. Let's talk about the most common and typical of them.
1. wrong place
The sad reality says that between the correct pipe laying and aesthetic component of the majority of people chooses the latter, unaware of what challenges the future may result in improper placement plumbing. Primarily, it is recommended to use a short tube for connection with the main part of plumbing water network. Equally important to keep the angle of inclination of the pipe. Siphons disposed close to the floor (or floor lying inside) should be placed as close as possible to the vertical.
Compliance with the recommendations described will allow water to relieve the unpleasant odor and "bubbling".
2. Lack of siphons
Each sanitary device, which is connected to the wiper system is required to have a separate siphon. It is installed in the gap between the tap and the pipe. What will happen if you do not put a trap? It's very simple - very soon the house of sewage will spread an unpleasant odor.
3. Small diameter pipes
When working with sewage should remember two things. First - it concerns the fact that the waste water to move independently under the influence of gravity, its own weight, right corner and put the pipe diameter. The second thing - is that size matters. The fact that the tube should not be too small. If you can not comply with the technical regulations, sewage problem, participants should be equipped with an additional pump.
4. leakage
Violation sewer pipe tightness may result in serious consequences for the entire dwelling. Remember that after finishing dwellings can be very difficult to get to the pipe. That is why the issue of integrity should be given the most attention. This is especially true in cases where PVC pipes are widely used in the sewer system.
5. Wrong bias level
Choose the right slope of the pipe is very important and very difficult. It must be not less than 2 and no more than 15 percent. If the slope in the pipe will be wrong, then eventually they will rapidly clog "precipitation", which will inevitably fall and accumulate in the waste water. All of these can cause serious and damaging consequences in the house.