Recently, more and more people are turning to the experts with a request to alter the chimney and the stove in the sauna. After they made a few mistakes on their own, of course.
In order to minimize the cost of correcting these errors, we present some of the most gross of them, the majority has tried to avoid them.
The absence of drain valve from the heat exchanger
In any iron stove has inside furnace (heat exchanger). At arrangement be embedded tee with a tap in the corrugated stainless steel tube. The absence of draining tap can lead to the fact that the external tank simply burst.
Heat exchanger without faucet live no more than one season (or even less), even if you do not drown the oven for a long time. Therefore, from the very beginning it is necessary to provide this important nuance.
Love bathe on weekends and can not imagine my life without the bathhouse? Put Like and subscribe to the channel "bath | From A to Z" !New articles every day!
Ceiling cutting is not insulated
If we consider this a mistake in terms of fire safety, there are no critical violations here you will not find. However, with the point of view of the furnace problems will be visible immediately when you first use the steam room during the cold season.
All the heat from the bath will go up to the attic, heat loss will be considerable need more materials for lighting, steam will not be long delayed. In general, the disadvantages are obvious. Insulation of the ceiling will help to solve these problems without the expense.
Poor penetration
You might miss the mark all bad sealant or not tightened "Master flash" with the self-tapping screws. Another reason - too much material cut off with a cuff, which is why the water flows directly to the pipe. There are many reasons, but the result is - the problem with the stove and the chimney.
Poor Assigned pipe
Attach the pipe must be carefully. Dangling communication to anything good will not. Fasten it to the rafters or crate. It is possible to use the amplified Papier profile, for example. It is cheap and cheerful.
Watch and state-of-sandwich pipes. If it's all rusted, leaking, then no binding or qualitative penetration will not help here. It is necessary to completely replace the defective item. And this time, it should be installed on all the rules.
Keep in mind that the replacement of the furnace or the flue does not always help to correct the shortcomings. The case may be in the construction of most buildings of bath. Poor insulation, originally incorrectly drawn up a plan of construction, cheap materials - all this is a partial list of reasons why your room is not functioning as it should. Consultation with a specialist to help determine the source of problems and give competent solution for a reasonable price.