Do you want to build a sauna? We build according to the law

  • Dec 24, 2019
click fraud protection

Unfortunately, that's it take, and to build a sauna at any point of your site is impossible. There are a number of standards that must be observed by all, without exception.

Firstly, all the buildings now need to register as a property. Do according to the rules - the evil uncle of the tax does not descend to you.

Secondly, if you suddenly decided that it would like to take and without registration, keep in mind that it is not put to the cadastral registration of the construction is illegal and subject to immediate demolition. In addition, the bath in principle problematic building, since it provides more and an increased risk (ie the risk of fire).

So during the construction of the bath you are responsible not only for the direct construction, but also for fire safety in his and neighboring area.

Standards bath erection on site

There are several important points, which should be available before the start of the design of future doubles.

Location on the site

According to the rules, a steam room must be built at a distance of 5 meters from the side of the street and 15 meters from the forest (if any). From the point of view of fire safety is important to maintain between the bath and the other buildings of a certain period.

instagram viewer

If the sauna is wood, the

  • save up to 10 meters of the stone buildings and other buildings of non-combustible materials;
  • 12 meters to keep structures partially of combustible material (such as of stone, but with wooden elements);
  • leave 15 meters from the wooden buildings.

If the steam is partially built of flammable material, the

  • 8 meters to the buildings of non-combustible materials;
  • 10 meters from the buildings of a partially combustible materials;
  • 12 meters to the wooden buildings.

And just in case the room built of non-combustible materials, provided:

  • 6 meters to the stone, and other fire-resistant buildings;
  • 8 meters to structures of partially refractory materials;
  • 10 meters to the non-refractory buildings (wooden).

We now turn to the sanitary norms. Here, too, has its own standards for the distance that must be met:

  • you want to keep at least one meter to the border with the territory of its neighbors;
  • Building up from the living baths should remain free space 8 meters (and owner of the site, and on the adjacent).

construction norms

Fire safety during construction, perhaps more important than the calculation of the distance:

  • floor area, which will be under the stove, you need to protect from fire. For this further lay plate (50x70 cm) along all firing (if the floor covering is made of combustible components);
  • The stove must have its own chimney, which is connected with the pipe. It is impossible to deduce the smoke through the ventilation;
  • The fuser is located at the inner walls of the pair. If the ceiling is made of combustible material, it must also protect its steel sheet (this applies to the wall, which is located close to the stove);
  • The wall, located opposite the stove, must be erected at a distance of 1.25 meters from it.

Sanitary norms:

  • waste water must be equipped with at least one meter away from the border with the neighboring territory;
  • It can not be used for interior decoration pair artificial materials (foam, plastic, etc.).